Cutler-Hammer Control Products
LIMIT SWITCHES
|
|
|
|
|
Full Size DIN EN50041 |
E50 Heavy-Duty
Plug-ln Switches |
E50 Heavy-Duty Factory Sealed
6P+ Switches |
Overview |
Two DIN body styles available. Nonmetallic housing, stainless steel hardware and modular
construction suits light industrial watertight/ oiltight OEM requirements |
Versatile in design. High reliability. Low maintenance costs with installation ease.
Best choice for Heavy-Duty Limit Switch applications. Withstands physical
and chemical abuse of harsh industrial environments |
Designed specifically to withstand
the penetrating properties of new cutting fluids (coolants), acid or
caustic washes, salt spray, severe vibration, shock and temperature
fluctuations, grit and debris |
Applications |
Packaging, material handling conveyors, end-of-travel and guarding operations, baler/compactor, industrial door
lifts
|
Punch presses, waste water treatment, machine tool, automotive, retrieval systems,
industrial truck, car wash lines |
Automotive, pulp and paper, food processing, waste management, primary metals, machine tool
(cutting, forming, bending) |
Product
Features |
Positive opening N.C. contacts,
forced break. Improved reliability in light welding conditions
Terminals are shielded to provide "finger- proof" protection to
VDE0106
Electrically isolated contacts eliminate polarity restrictions
Enclosure housing is double insulated to IECNDE specifications
Backed-out wire-ready :I: terminal screws. Identification to both US
and IEC designations
Miniature DIN operating head easily
locks to switch body with 1/4 turn bayonet base mount
Mechanical life -10,000,000 operations minimum
Electrical life -500,000 operations
minimum at full load |
Modular operating heads, switch
bodies and receptacles are interchangeable with- outfield adjustment
Order as complete assemblies or components for stocking and
manufacturing flexibility
90 degree total travel, 5 degree
pre-travel characteristics are standard features
VITON gasket, boot, and seal material offers exceptional
chemical resistance
Rotary head operating mode from CW, CCW or CW and CCW is
easily changed without tools
Keyed, four directional head positioning
Mechanical life -13,000,000 operations minimum
Electrical life -1,000,000 operations
minimum at full load (single pole)
|
Tamperproof, one-piece switch
body assembly, epoxy filled
Factory sealed. 6P submersible.
Pre-wired with cable, pigtail or pin
connector options. All with ground connection
Utilizes E50 modular operating heads
Special V-seal on switch body/head connection provides hermetic
barrier against fluid ingress
LED indicating light, 24V -120V AC/DC.
Neon version too
Peel off see-through painting mask over nameplate
Mechanicallife-35,000,000 operations minimum
Electrical life -1,000,000 operations
minimum at full load
|
|
|
|
|
|
E47BCC Compact Prewired |
E47 Precision Switches |
Miniature
DIN
EN50047 |
Overview |
Designed to be a versatile, slim
device for hard to fit applications where sealing integrity is required |
Specified when accurate
repeatability, choice of operating forces and travel characteristics
and tightly controlled action of cam or target in space restricted areas
is of prime importance. Cost effective and compact |
Two DIN body styles available. Nonmetallic housing, stainless steel hardware and modular
construction suits light industrial watertight/ oil-tight OEM requirements |
Applications |
Machine tool, food processing and packaging
|
Overhead, folding and elevator doors, sliding gates, automated guided vehicles and
commercial instrumentation |
Packaging, material handling conveyors, end-of-travel and guarding operations, baler!
compactor, industrial door lifts |
Product
Features |
Rugged aluminum alloy die cast
housing
Sealed construction with enclosure ratings of NEMA 4, 6 and 13
Pre-wired with 3mof 18 AWG,AWM2517, 300V
cable
Stackable ridge for ganged operation
|
Self-contained switches or with an
enclosed cast housing for increased durability and conduit connection (1/2"
NPT)
High current capacity for power load switching and motor handling
capability
Screw and solder terminations
Booted enclosed version shields actuators from debris
Mounting centers-l.0 in (25.4mm) #8 screw size
Operating Temperature' Basic Type: -25° to 80°C
Enclosed Type: -15°to 80°C
Mechanical life -3,000,000 operations minimum
Electrical life -500,000 operations
minimum
|
Positive opening N.C. contacts,
forced break. Improved reliability in light welding conditions
Terminals are shielded to provide "finger- proof' protection to VDE0106
Electrically isolated contacts eliminate polarity restrictions
Enclosure housing is double insulated to IECNDE specifications
Backed-out wire-ready ; terminal screws. Identification to both US
and IEC designations
Miniature DIN operating head easily
locks to switch body with 114 turn bayonet base mount
Mechanical life -10,000,000 operations minimum
Electrical life -500,000 operations
minimum at full load
|
|
|
|
|
|
Non Plug-ln Switches |
Hazardous Location Switches |
Special Purpose Switches |
Overview |
The Industrial standard for Non
Plug-ln Heavy-Duty Limit Switches. Sold as complete assembled units
only |
Designed for severe environmental
service in locations where there exists a danger of an internal or
external explosion of flammable gases, vapors, metal alloy or grain
dust |
Variety of special function limit
switch products |
Applications |
Serving MRD and USER replacement requirements with broad market coverage
|
Mining, metal cutting, grain storage, forest products, petrochemical, waste and sewage
management, pharmaceutical |
Serving MRO and USER replacement require- ments with broad market coverage |
Product
Features |
Side and top rotary, side and top
push or wobble operation
CW, CCW or CW and CCW operating modes are field
convertible
Double break-make snap action contacts, same polarity each pole
Captive saddle clamp terminals accept up to #12 wire
Head can be mounted in any offour discrete positions, intervals of 90
degrees
Mechanical life -10,000,000 operations minimum
Electrical life -500,000 operations
at full load
|
Sealed and unsealed versions
available
One-way gasket on sealed version keeps
liquids out, yet allows a harmless release of gases in the event of an internal explosion
Silicon bronze housing provides excellent corrosion resistant
properties in extreme NEMA 4X applications
Temperature build-up on limit switch surface is dissipated by
housing design and
materi- als used
Utilizes the operating heads and internal switch mechanisms of the
10316 Non Plug-ln line
NEMA7,Div.l,Classl,BCD
NEMA9,Div.l,Classll,EFG
|
Special function switch lines
include, cabinet door interlocks when plunger is pulled out, red band indicator visually shows that
interlock is defeated
Precision switches-1N.O.-1N.C
2N.O.-2N.C., or operator only
Variety of mounting brackets available
Pneumatic time delay- ON delay and OFF
delay. 1iming range -0.05 to 60 seconds
Rotating cam shaft switches
|
|
For Ordering or Product
Info email : edp@munroelectric.com
|